Model No.: RSD2001A

RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate.

Name:Multi-Parameter Patient Monitor 8 Inch
Item no:RSD2002
 
 
Details:
Features:
 
1.Portable , streamline handle design,big-front display;
2.ECG/HR/RESP/TEMP/ NIBP/SPO2 customer optional;
3.8 inch color TFT (diagonal) display, resolution 800X600;
4.Full-lead ECG, 6 channels display simultaneously;
5.13 kinds of arrhythmia & 2 channels S-T segment detection auto-analysis;
6.Maximum 24 hours graphic and tabular trends of all parameters;
7.50 VPC events; 20 minutes ECG waveform recall;
8.Against electrosurgical interference and defibrillation.
Specifications:
 
ECG
CMRR: >/=90dB
HR Measure and Alarm Range: 15-300bpm
Accuracy: +/-1bpm
Heart Rate Average: 8 beats
ST Segment Range: -0.8 to +0.8mV
Pacemaker suppression on PR: Amp: +/-2mV to +/-9mV
Range: 0.2ms to 2.0ms
Connector: AAMI 6-1 pi
Lead Selection: I, II, III, V, aVR, aVL, aVF
Lead Off Alarm: Visual and audible
Input: 5-lead ECG cable
QRS Indicator: Visual and audible
Sweep Speed: 12.5 /25 /50mm/s
Amplitude Selection: x1/4, x1/2, x1, x2, x4
Trend: 2 hours ,-4 hours ,-8 hours, -24 hours and -48 hours
Frequency Response:
Monitoring: 0.5 to 35Hz (+0.4dB, 3.0dB)
Surgical: 0.5 to 25 Hz (+0.4dB, 3.0dB)
Heart Rate Alarm Time: Less than 7 seconds
Aspect Ratio: 0.24~0.6sec/mv
Defibrillation Protection: 5kV test
Recovery Time after Defibrillation: Less than 5 seconds.
RESP
Measurement Mode: Thoracic Impedance
Respiration Rate and Alarm Range: 0-150brpm +/-2brpm
Waveform Display Speed: 6.25, 12.5 and 25mm/s
Refresh time: Approx. 2 seconds
TEMP
Measurement and Alarm Limit: 0-50 degrees
Probe: Skin surface or rectal /esophageal)
Unit: Celsius/Fahrenheit
Accuracy: +/-0.1 degrees
Resolution: 0.1 degrees
Refresh time: Approx. 4 minutes
NIBP
Measurement Method: Oscillometric
Parameters: Systolic, Diastolic, Mean, Pulse
Unit: mmHg or kPa
Operation Mode: Auto, Manual, STAT
Measurement and Alarm Range:
Systolic Pressure:
Adult/pediatric: 30-254mmHg (4.0-33.9kPa)
Neonate: 30-135mmHg (4.0-18.0kPa)
Diastolic Pressure:
Adult/pediatric: 10-220mmHg (1.3-29.3 kPa)
Neonate: 10-110mmHg (1.3-14.7kPa)
Cuff Pressure Range:
0-280mmHg (0-37.3kPa)
Initial Cuff Inflation Pressure:
Adult/Pediatric: 170+/-10mmHg (22.7 +/-1.3kPa)
Neonate: 90+/-10mmHg (16.0+/-1.3kPa)
Deflation Pressure: 30mmHg (4.0kPa) higher than last systolic pressure.
Cuff Inflation Speed: Not greater than 50mmHg /sec
Measurement Time:
It can not be chosen in Manual/Stat mode.
1s, 10s, 15, 30s, 60s, 90s, 120s, 180, 240s, 480s can be selected in
Auto mode.
Measurement Display Accuracy: +/-3mmHg
BP pulse Accuracy:
40~200bpm: +/-3bpm
200~240bpm: +/-5bpm
Cuff: Neonate, infant, small child, child, small adult, adult
SpO2
Measurement and Alarm Range: 0-100% Adult/Pediatric/Neonate
SpO2 Average: 8 beat average
Accuracy: +/-2% (90-100%), +/-3% (50-89%)
SpO2 Pulse Rate Range: 30-250bpm
SpO2 Pulse Rate Average: 8 seconds
SpO2 Pulse Rate Accuracy: +/-2% (30-100bpm)
Refresh Time: Approx. 2 seconds
Pulse Rate Alarm Limit: 0-250bpm
Pulse Sound: Pulse sound indication
Sensor Type: Finger clip, universal Y, silicone soft
Internal LED waveform: infrared
Pulse Rate Display: Digit
Environment                           
Temperature: working 0 degrees-45 degrees;           
transport and storage :-25 degrees-85 degrees;               
Humidity: working 30%-85%(non-condensing);
transport and storage :30 degrees-95 degrees(non-condensing)
Dimension:190(W)X230 (H)X160(D) mm
Weight: 3KG
 
Standard Configuration
1 Main unit
 
CONFIGURATION I ECG,HR,RESP,TEMP
CONFIGURATION II ECG,HR,NIBP
CONFIGURATION III ECG,HR,SpO2
bigPhoto
 Ms. stella wang

Tel: 86-0755-86330963
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

RONSEDA ELECTRONICS CO.,LTD.CHINA [China (Mainland)]


Business Type:Manufacturer
Country/Region: China (Mainland)

You May Like:

Product (57)